Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Acta ortop. bras ; 18(2): 75-78, 2010. ilus, tab
Article in Portuguese | LILACS | ID: lil-545174

ABSTRACT

OBJETIVO: Avaliar a relação entre lesões abdominais e a introdução de fios guia em ensaios cirúrgicos do quadril, propor um sistema de escorização e conduta médica em função da distância percorrida pelo fio guia a partir da placa quadrilátera e a estrutura anatômica lesionada. MATERIAL E MÉTODOS: Utilizou-se 18 quadris de cadáveres, um fio de Steimann de 3.2 x 300 mm, um perfurador elétrico e um paquímetro. Introduziu-se o fio no centro do colo femoral por via de acesso lateral no quadril sob visualização direta. Por via de acesso abdominal mediana longitudinal estendida à região pélvica, observou-se a placa quadrilátera até o fio a transfixar. A partir deste ponto, prolongou-se a inserção por mais 140 mm, a fim de observar seu trajeto abdominal e descrever as lesões apresentadas em função da distância percorrida. RESULTADOS: Houve cinco (27 por cento) lesões de cólon sigmóide e uma (5 por cento) lesão transfixante do nervo obturador. Artérias e veias ilíacas comuns contra laterais ao quadril fixado não foram lesionadas. CONCLUSÃO: O fio guia não deve ultrapassar a placa quadrilátera. Medidas de prevenção são importantes no pré e intra-operatório e o escore e a conduta médica propostos neste estudo devem ser criteriosamente observados nos casos de lesão comprovada.


OBJECTIVES: Evaluate the relationship between abdominal injuries and the introduction of guide wire in experimental hip surgery, to propose a scoring system and a medical management based on the distance traveled by the guide wire from the quadrilateral plate until the damaged anatomical structure. MATERIAL AND METHODS: 18 cadaveric hips, a Steimann pin of 3.2 x 300mm, an electric drill and a caliper were used. The wire was inserted in the center of the femoral neck through a lateral approach in the hip under direct visualization. Via median abdominal extended approach to the pelvic region, the quadrilateral plate was observed until the wire crossed it. From this point the wire was further inserted 140 mm in order to observe its abdominal path and describe the lesions presented based on the distance traveled. RESULTS: There were five lesions (27 percent) in the sigmoid colon, and one transfixing injury (5 percent) of the obturator nerve. The common iliac arteries and veins from the contralateral hip were not injured. CONCLUSION: The guide wire must not exceed the quadrilateral plate. Preventive measures are important in the pre- and intra-operatory stages and the score and medical management proposed in this study should be carefully observed in cases of injury.


Subject(s)
Humans , Adult , Bone Wires , Colon, Sigmoid/injuries , Bone Wires/adverse effects , Hip Fractures , Obturator Nerve , Abdominal Injuries/etiology , Abdominal Injuries , Cadaver , Abdominal Injuries/rehabilitation
SELECTION OF CITATIONS
SEARCH DETAIL